Y1-03-0223 Rev. D
Resizing Handle
In the status bar‟s bottom right corner there is a resizing-handle. By dragging the handle you can adjust the size of
the main window to your preference.
APPENDIX A - TROUBLESHOOTING
Problem
Cause
Solution
Unable to connect to the
Nauticast-B AIS
Incorrect connection data
Verify data (IP-address, COM-Port, etc.). If
not sure, contact your administrator
Not connected to network
or cable
Check if your computer and the
Nauticast-B have connection to the
network (IP-connection) or the same serial
cable (serial connection)
Nauticast-B not
configured correctly
Contact your service partner
Static data configuration
settings not loaded
Enquiry not successful
Close form and re-open it
Load settings not provided
for this sentence
See standard for more information
No output in Console Log
or Message View
Not connected
Connect to the Nauticast-B
No output types selected
Select output types