32 Programmer’s Guide
Soft Limit Enable
By default, positive and negative software limits are disabled. You
can enable the limits by setting the appropriate control bits (bit 22=
positive software limit enable, bit 23= negative software limit
enable). You can also control the software limits using the SLIM
command.
SLIM Software Limits
Value Description
0 Disables positive limit and negative limit
(default)
1 Enables positive limit and disables
negative limit
2 Disables positive limit and enables
negative limit
3 Enables positive limit and negative limit
In the Configuration Wizard, you can enable hardware limits in the
Faults dialog.
Software Limit Positions
You cans specify the positions for software limits using the SLM
command.